Sick RLY3-LOOP100, Safety relays, ReLy, SKU: 1100696
Technische Daten
- Gewicht
- 1 kg
Produktbeschreibung
- Applications: Evaluation unit
- Compatible sensor types: Flexi Loop safe series connection
- Safety integrity level: SIL 3(IEC6150
- Category: Category 4(ISO13849
- Performance level: PLe(ISO13849
- PFH D (mean probability of a dangerous failure per hour): 1.5 10 9
- T M (mission time): 20years (ISO13849
- Stop category: 0(IEC60204
Flexi Loop monitoring:
- Restart interlock:
- Reset: Automatic Manual
External device monitoring (EDM):
- Connection type: Front connector with spring terminals
- Inputs: 2safety inputs 1input for reset pushbutton or external device monitoring (EDM)
- Outputs: 3enabling current paths (safe) 2application diagnostic outputs (not safe) 1test pulse output (not safe)
- Display elements: LEDs
- Configuration method: Hard wired DIPswitch
- Voltage supply: PELV or SELV
- Supply voltage V S : 24VDC (16.8V... 30V)
- Residual ripple: 2.4V
- Power consumption: 2.5W (DC)
Safety inputs:
- Number: 2
- Input voltage HIGH: 24VDC (11V... 30V)
- Input voltage LOW: 0VDC (3V... 5V)
- Input current: 4mA... 6mA
- Activation time tolerance between the two start buttons: 3s
Reset pushbutton or external device monitoring (EDM) input:
- Number: 1
- Input voltage HIGH: 24VDC (11V... 30V)
- Input voltage LOW: 0VDC (3V... 5V)
- Input current: 4mA... 6mA
Enabling current paths:
- Response time: 79ms
- Number: 3
- Type of output: N/O contacts, positively guided
- Contact material: Silver alloy, gold flashed
- Switching voltage 10VAC... 230VAC; 10VDC... 230VDC
- Switching current: 10mA... 6A
- Total current: 12A
- Mechanical life: 1x10 7 switching cycles
- Overvoltage category: III (EN60664
- Rated impulse withstand voltage U imp : 6kV (EN60664
Applica