Euchner CET2-AR-CDA-AH-50X-SH-112446, Safety switch with guard locking and integrated evaluation electronics, P\n: 112446
- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6500 N
- Up to 20 switches in series
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Up to category 4/PL e according to EN ISO 13849-1
- With plug connector M23 (RC18)
- Unicode
- Teach-in input
- With double ramp
- Approach direction A and C (default setting on delivery)
Approach direction Horizontal Can be adjusted in 90° steps Safety switchThe device may be operated only in conjunction with the actuator CET-A-.... Important: The actuator must be ordered separately. Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Only the last actuator taught in is detected. Solenoid operating voltage
- DC 24 V +10% -15%
Guard locking type
- CET2: Open-circuit current principle guard locking by solenoid force. Activation of the guard locking by applying voltage to the guard locking solenoid.
- LED State: Status LEDLED DIA: Diagnostic LEDLED 1 rd: freely configurableLED 2 gn: freely configurable
- OUT: Monitoring output (semiconductor)RST: Reset inputJ: Teach-in input
- Category 4/PL e according to EN ISO 13849-1
Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated. The category is dependent on the installation position of the safety switch: Dimension drawing Block dia