Sick DFS60S-TAOC01024, Safety encoders, DFS60S Pro, SKU: 1096943
Technische Daten
- Gewicht
- 1 kg
Produktbeschreibung
- Safety integrity level: SIL 2 (IEC 61508), SILCL2 (IEC 62061) 1)
- Performance level: PL d (EN ISO 13849) 1)
- Category: 3 (EN ISO 13849)
- PFH (mean probability of a dangerous failure per hour): 1.7 x 108 2)
- TM (mission time): 20 years (EN ISO 13849)
- Safetyrelated measuring step: 0.09° , Quadrature analysis
- Safetyrelated accuracy: ± 0.09°
- Sine/cosine periods per revolution: 1,024
- Measuring step: 0.3 ″ , For interpolation of the sine/cosine signals with e.g. 12 bit 1)
- Integral nonlinearity: Typ. ± 45 ″ (without mechanical tension of the stator coupling)
- Differential nonlinearity: ± 7 ″
- Communication interface: Incremental
- Communication Interface detail: Sin/Cos 1)
- Initialization time: 50 ms 2)
- Output frequency: ≤ 153.6 kHz
- Power consumption: ≤ 0.7 W (without load)
- Load resistance: ≥ 120 Ω
- Connection type: Male connector, M12, 8pin, radial
- Supply voltage: 4.5 ... 32 V
- Reference signal, number: 1
- Reference signal, position: 90° , electronically, gated with Sinus and Cosinus
- Reverse polarity protection: ✔
- Protection class: III (according to DIN EN 61140)
- Shortcircuit protection of the outputs: ✔ 1)
- Mechanical design: Through hollow shaft
- Shaft diameter: 6 mm
- With feather key groove
- Weight: Approx. 0.25 kg 1)
- Shaft material: Stainless steel
- Flange material: Diecast zinc
Produktangebot
731,37 €
870,33 € inkl. MwSt. zzgl. Versandkosten
Lieferzeit ca. 4 Tage
Sichere Zahlung
Rechnung
Schneller Versand
etc.
Fragen zum Produkt?
Kennzeichnungen
- Artikeltyp
- Active Components/Sensors/Encoders